Superior Grouting holds more than 35 years of experience in the grouting industry. Additionally, superior grouting services inc is known for using the most effective tools and state-of-the-art tools in offering clients with the most effective outcomes.
WHAT WE DO?
We provide solutions in conventional and non-conventional grouting approaches and focus on difficult tasks that call for technical knowledge, product modern technology, and customized tools, combined with skilled experience.
We are a specialty grouting professional with abilities including mobile grouting, slurry grouting, compaction grouting, chemical grouting as well as polyurethane grouting for the concrete raising of all kinds of concrete frameworks. We provide solutions in conventional and non-conventional grouting approaches and focus on difficult tasks that call for technical knowledge, product modern technology, and customized tools, combined with skilled experience.
Our objective is to provide knowledgeable technological knowledge and tailored remedies to the most difficult concerns of geotechnical engineering. This knowledge has gained us the count on of community, state, and government agencies, as well as the basic economic sector. We intend to provide ingenious and reliable remedies for all your specialty grouting demands.
35 FOUNDED YEARS IN EXCELLENCE SOLUTION
Few firms can state that– yet we can, and we improve our experience everyday. Our comprehensive experience and trusted leadership in intricate grouting and structure remedies have made Superior Grouting Services leaders in locating geotechnical remedies. With a long performance history of efficiency in the general public and economic sectors, we pride ourselves on dependability, stability, and solution. This continued success is rooted in our individuals, that make every effort each and every day to make superior grouting services inc the most effective at what it does.
SAFETY AND ALSO WELLNESS PROGRAM
We see safety and security as the highest priority that prolongs from the task throughout all levels of the firm. For us, safety and security is not a motto; it is a value instilled in our culture. It is a deliverable to our clients in the same way that expense, top quality and schedule are deliverables. Our Security & Health and wellness Program is incorporated right into our procedure. It needs preplanning of job activities to guide the implementation of safe job steps.
Our employees attend various detailed safety and security training programs with the Houston Area Security Council and extra courses that are commonly site/company-specific. This permits us to include the well being of each and every person related to a task as a function of the safety and security procedure and is a key element to keeping a job on schedule and within budget.
STUDY – CENTURY ASPHALT ROCK CRUSHER
DIFFICULTY
Century Asphalt constructed a new asphalt plant in Houston, TX. The site had formerly been a garbage dump. The structure design to support the rock crusher was a 50FT lengthy x 14FT wide x 5FT thick concrete pad with concrete columns expanding upwards to establish the rock crusher on. The complete weight of the concrete structure with rock crusher was roughly 750,000 extra pounds. Once the rock crusher was placed into operation, the structure cleared up 14 inches in one area and was twisted out of degree to different levels throughout the remainder of the structure. The settlement concern took place due to constant intense resonance of the rock crusher, while in operation, subjecting the weak subgrade underneath the structure. Reduced above clearance, to access the structure and perform the job even more complicated the fixing procedure. On top of that, it was of critical importance that the structure is within an 1/8-inch tolerance of degree throughout, due to the operating requirements of the rock crusher.
REMEDY
- was contracted to support and level the rock crusher structure using the upstage compaction grouting procedure. Checking was executed to determine the depth of load-bearing dirts. Two-inch ID, high-pressure seamless pipeline, were set to a 32FT depth on an approximate 5FT grid pattern. A reduced movement 0 to 1-inch downturn, cement-based grout, was infused at high pressure to densify the existing subgrade dirts. The procedure was duplicated in 2FT lifts to the top of the grouted zone. The structure was checked for lift constantly throughout the procedure. The roughly 750,000-pound structure was stabilized and increased to within the required tolerance.
TASK RECAP
Upon completion of the fixing, the plant was placed into operation. Century Asphalt checked the structure for the tiniest of activity, on a regular basis, over the duration of a year and beyond. No activity has been identified to day.